M4 compact limit switches

M4 Series Miniature Limit Switch with molded cable.
IP67-sealed in a rugged metal housing.
Lifetime of maximaal 10 million circuits.
Standard cable length 2 or 3 meters.
To customer specifications in other Langen.
A 230 VAC switching capacity, with NO / NC.

M4 Compact limit switch.
Cast in metal enclosure, available with a variety of different control elements.
IP67 sealing.
Standard cable length 2 and  3 meters.
Optional connection of the Plugs on the side.

Features :

  • Miniature Size & Positive opening contact switch inserted for option.
  • Wide range of choice.
  • Protective grade conforms to IP 67.
  • With 2m or 3m cable. (VCTF or SJTO cable).
  • SJTO cable (UL approved) Oil resistance cord type.
  • Standard type, side out cable type, Quick connect type.(M12 x 1).

STANDARD TYPE :

ORDERING CODE :

Cable code : cable type ; cable length

VCTF Cable(0.75mm2 x 4c)
SJTO Cable (UL approved)(18AWG x 4c)
ELECTRICAL RATING5A 125 or 250 V AC
3A 30 V DC
0.4A 125 V DC

CIRCUITRY :

Side Out Cable Type :

ORDERING CODE :

Connector Style :

AC → For AC or AC/DC Quick Connect Style

DC → For DC Quick Connect Style

Quick Connect Type (M12 x 1) :

Connector Cable :

CHARACTERISTICS :

Operating speed0.1mm ~ 0.5m/s,
M4-4104(4114) -> 1mm ~ 1m/s
Operating Temperature-20 ° C ~ +70 ° C (Without freezing)
Humidity95% RH Max
Operating FrequencyMechanically : 120 operations/min.
Electrically : 30 operations/min
Contact resistance300m Ω / Max. (initial) (with 3m Cable)
Insulation resistance100M Ω / Max. (550V/DC).
Dielectric strengthBetween non-continuous terminals: 1000V AC 50/60Hz i minute.
Between each terminal and non-current-carrying metal part and
Between each terminal and ground : 1500V AC 50/60Hz i minute
VibrationMalfunction durability : 10~50Hz ; 1.5mm double amplitude
ShockMechanically durability : 1000 m/sec2 (approx 100G)
Malfunction durability : 300 m/sec2 (approx 30G)
Service lifeMechanically : 2,000,000 operations min.(Standard)
500,000 operations min.
(Positive Opening Contacts)
Electrically : 200,000 operations min,(1.5A,110VAC)MAX.
Protection DegreeIEC : IP67

ORDER Code

AC TYPE DC TYPE Cable length
M4-QAC-2 M4-QDC-2 2m
M4-QAC-4 M4-QDC-4 4m
M4-QAC-6 M4-QDC-6 6m
Get a Quote